explosion proof air conditioners

MATTICKS INDUSTRIES, INC.

explosion proof air conditioners

KOOLGUARDTM

ROOF MOUNT COMBO

AIR CONDITIONING & PRESSURIZING

FOR HAZARDOUS LOCATIONS

"COOLING ONLY"

R-410A

CLASS 1, GROUP BCD, DIVISION 2 EXTERIOR

GENERAL PURPOSE INTERIOR

NFPA 496 FOR Y, OR Z PRESSURIZING


Self Contained Remote Controls

Cooling Only

230 Volt 1Ph , 230 Volt 3Ph, 460 Volt 3Ph @ 60Hz

Features:

Heavy duty ultra-quite operation for versatile applications such as new construction, modular analyzer shelters, control rooms, electronic equipment shelters, battery rooms, chemical storage containers, and many other hazardous locations that require environmental control.

Aluminum finned copper coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency.

Twin indoor blowers for the a/c side: Move air quietly. Single speed blower motor provides maximum room circulation and low static operation.

Compressors: Reciprocating compression designed to withstand higher compressor ratios. Scroll compressors for increased efficiency, quieter operation and reliability on 4 and 5 ton models.

Dust Filters: One inch disposable air filters are standard with the return air filter grill and are replaceable from the room side.

Easy Installation

Fresh Air Stack 12" to 16" opening (Acees on back of the unit or on the side) for Fresh Air for 25ft above grade level

Options:...

Polyurethane enamel or Herisite corrosion protected hermetic system, includes evaporator coil, condenser coil, compressor, and all connecting tube

Loss of flow Alarm Contacts

Low Ambient Control

Stainless Steel Housing

Cooling Only Models :

18,000 BTU to 56,000 BTU @ 230/208 Volt 1Ph 60Hz

24,000 BTU to 70,000 BTU @ 230/208 Volt 3Ph 60Hz

31,000 BTU to 67,000 BTU @ 460 Volt 3Ph 60Hz

Pressurizer Section:

The Combo Units are offered with 2000 to 5000 CFM pressurizers

All Pressurizers are PLC Operated with Variable Speed Control

 

SPECIFICATIONS - 230/208 Volt 1Ph UNITS

 MODEL  COOLING CAPACITY
BTU/HR
 A/C UNIT ELECTRICAL RATINGS  A/C UNIT AIR MOVING CAPACITY  PRESSURIZER  RATINGS  PRESSURIZER  CFM
 VOLTS AMPS WATTS CIRCUIT RATING  VOLTS AMPS CIRCUIT RATING
 MBC2184A-GP-BCD-P  18,300  230/208  11.7/12.4  2691/2579  20A  845 CFM  230/208  2.3/2.4  10A  2000
 MBC2244A-GP-BCD-P  24,000  230/208  16.2/17.6  3500/3270  30A  905 CFM  230/208  2.3/2.4  10A  2000
 MBC2314A-GP-BCD-P  29,600  230/208  18.4/20.0  4730/4390  35A  1270 CFM  230/208  2.3/2.4  10A  2000
 MBC2364A-GP-BCD-P  35,400  230/208  22.6/24.4  5410/5180  35A  1270 CFM  230/208  2.3/2.4  10A 2000
 MBC2434A-GP-BCD-P  43,000  230/208  25.5/27.7  6920/6620  50A  1665 CFM  230/208  2.3/2.4  10A 2000
 MBC2474A-GP-BCD-P  47,000  230/208  28.8/30.7  7360/7080  50A  1665 CFM  230/208  2.3/2.4  10A 2000
 MBC2574A-GP-BCD-P  57,000  230/208  31.4/31.3  9500/8700  60A  1665 CFM  230/208  2.3/2.4  10A 2000
                     

SPECIFICATIONS - 230/208 Volt 3Ph UNITS

 MODEL  COOLING CAPACITY
BTU/HR
 A/C UNIT ELECTRICAL RATINGS  A/C UNIT AIR MOVING CAPACITY  PRESSURIZER  RATINGS  PRESSURIZER  CFM
 VOLTS AMPS WATTS CIRCUIT RATING  VOLTS AMPS CIRCUIT RATING
 MBC2244B-GP-BCD-P  24,000  230/208 12.4/15.7  2852/5345  20A  905 CFM  230/208  2.3/2.4  10A  2000
 MBC2314B-GP-BCD-P  29,600  230/208  14.2/15.2  3266/3161  20A  1270 CFM  230/208  2.3/2.4  10A  2000
 MBC2364A-GP-BCD-P  35,400  230/208  18.5/19.8  4255/4118  30A  1270 CFM  230/208  2.3/2.4  10A 2000
 MBC2434B-GP-BCD-P  43,000  230/208  19.8/21.3  4554/4430  35A  1665 CFM  230/208  2.3/2.4  10A 2000
 MBC2474B-GP-BCD-P  47,000  230/208  22.7/21.0  5221/4368  50A  1665 CFM  230/208  2.3/2.4  10A 2000
 MBC2574B-GP-BCD-P  57,000  230/208  22.3/24.0  5129/4992  60A  1900 CFM  230/208  2.3/2.4  10A 2000
 MBC2694B-GP-BCD-P  69,000  230/208  33.3/36.9  9500/8700  60A  1900 CFM  230/208  2.3/2.4  10A 2000
                     

SPECIFICATIONS - 460 Volt 3Ph UNITS

 MODEL  COOLING CAPACITY
BTU/HR
 A/C UNIT ELECTRICAL RATINGS  A/C UNIT AIR MOVING CAPACITY  PRESSURIZER  RATINGS  PRESSURIZER  CFM
 VOLTS AMPS WATTS CIRCUIT RATING  VOLTS AMPS CIRCUIT RATING
 MBC2314C-GP-BCD-P  31,000  460  10.8  4968  15A  950 CFM  460  1.2  5.0A  2000
 MBC2364C-GP-BCD-P  35,400  460  11.5  5290  15A  1270 CFM  460  1.2  5.0A 2000
 MBC2434C-GP-BCD-P  43,000  460  12.3  5658  15A  1665 CFM  460  1.2  5.0A 2000
 MBC2474C-GP-BCD-P  47,000  460  13.3  6118  20A  1665 CFM  460  1.2  5.0A 2000
 MBC2574C-GP-BCD-P  57,000  460  13.8  6348  20A  1900 CFM  460  1.2  5.0A 2000
 MBC2674C-GP-BCD-P  67,000  460  14.8  6808  25A  1900 CFM  460  1.2  5.0A 2000
                     

DEMINSIONAL SPECIFICATIONS w/o Pressurizer Section

 MODEL  LENGTH  HEIGHT  WIDE  SUPPLY AIR OPENING  RETURN AIR OPENING
 18,000 - 24,000 BTU 90" 36" 36" 19.88" x 7.88" 19.88" x 11.88"
 30,000 - 36,000 BTU 90" 36" 40" 27.88" x 7.88" 27.88" x 13.88"
 43,000 - 57,500 BTU 95" 36" 44" 29.88" x 9.88" 29.88" x 15.88"
  69,500 BTU 95" 46" 44" 29.88" x 9.88" 29.88" x 15.88"
           

Matticks Industries, Inc. © 2020 | All Rights reserved